Koel iGreen Offerings
Features
Compact Product: |
Unmatched space efficiency |
Low OPEX: |
Best in class fuel efficiency with O2E technology |
Robust and Reliable Product: |
Lowest maintenance and trouble free product with Kirloskar Air Cooled Engines |
Compliance: |
Latest Government Emission Norms CPCB II |
Start Type: |
Controller Based Easy Push Start Type |
Customer Service: |
Quick and affordable door step service coverage (420+ service touch points and 6000+ KOEL trained service professionals on field) |
Warranty: |
2 years warranty* & labour free onsite service under warranty period |
Prime Rating at rated rpm (as per ISO 8528) |
kVA |
5 |
7.5 |
10 |
12.5 |
|
kW |
4 |
6 |
8 |
10 |
||
Genset Model |
KG1-5AS3 |
KG1-7.5AS4 |
KG1-10AS5 |
KG1-12.5AS2 |
||
Frequency |
Hz |
50 |
50 |
50 |
50 |
|
Power Factor |
lagging |
0.8 |
0.8 |
0.8 |
0.8 |
|
Voltage |
V |
230 (1Ø) & 415 (3Ø) |
230 (1Ø) & 415 (3Ø) |
230 (1Ø) & 415 (3Ø) |
230 (1Ø) & 415 (3Ø) |
|
Governing class (As per ISO 8528 Part – V) |
G2 |
G2 |
G2 |
G2 |
||
Noise Level |
dBA |
<75 |
<75 |
<75 |
<75 |
|
Fuel Consumption* |
At 100% Load |
Ltrs/Hr |
1.6 |
2.21 |
3 |
3.45 |
At 75% Load |
1.3 |
1.62 |
2.4 |
2.65 |
||
At 50% Load |
1 |
1.21 |
1.8 |
1.94 |
||
Fuel Tank Capacity |
Ltrs |
50 |
50 |
50 |
50 |
|
Weight of Genset with canopy° |
Dry |
Kg |
670 |
680 |
750 |
840 |
Wet |
720 |
730 |
800 |
890 |
||
Overall Dimensions of Genset^ |
Length |
mm |
1417 |
1767 |
1767 |
1767 |
Width |
820 |
820 |
820 |
820 |
||
Height |
1321 |
1328 |
1328 |
1321 |
||
Electrical Battery Starting Voltage |
Volts-DC |
12 |
12 |
12 |
12 |
|
Engine |
||||||
Engine Model |
EA10 G1 |
EA10G1 |
EA16G1 |
EA16G1 |
||
Rated output (Prime Continous rating as per ISO 8528-1 |
kW |
7.3 |
7.3 |
11.8 |
11.8 |
|
HP |
10 |
10 |
16 |
16 |
||
No. of Cylinder |
Number |
1 |
1 |
2 |
2 |
|
Cubic Capacity2 |
Ltrs |
0.95 |
0.95 |
1.56 |
1.56 |
|
Bose x Stroke |
mm |
102x116 |
102x116 |
95x110 |
95x110 |
|
Rated Speed |
RPM |
1500 |
1500 |
1500 |
1500 |
|
Aspiration |
NA/TC/TA |
NA |
NA |
NA |
NA |
|
Lube Oil Change Period |
hrs |
500 |
500 |
500 |
500 |
|
Lube Oil Sump Capacity |
Ltrs |
3.5 |
3.5 |
6.5 |
6.5 |
|
Cooling Mechanism |
Air Cooled |
Air Cooled |
Air Cooled |
Air Cooled |
||
Coolant Capacity |
Ltrs |
NA |
NA |
NA |
NA |
|
Alternator |
||||||
Insulation Class |
Class H |
Class H |
Class H |
Class H |
||
Alternator Efficiency (at 100% load) 0.8pf** |
% |
78.1 |
82.5 |
82.6 |
84.9 |
|
Max Voltage Dip at Full Load 0.8 pf Lag |
sec |
<20% |
<20% |
<20% |
<20% |
|
Max Time to build up rated voltage at ated RPM |
<5 sec provided engine reach the rated speed |
<5 sec provided engine reach the rated speed |
<5 sec provided engine reach the rated speed |
<5 sec provided engine reach the rated speed |
Notes:
- ^ Tolerance Apply, *with 0.845 Specific Graity of Diesel (5% Tolerance)
- ** Efficiency of Alternator as per standards IS 4722 and IEC 34-1
- °These weight are for handling & transportation only
- For Site Conditions other standard operating conditions consult available Prime Power
Disclaimer:
Due to continuous improvement in product on the basis of market feedback above specification are subject to change with out any prior notice. Please contact authorized dealer/distributor for latest specification.