180 kVA – 250 kVA

 

Features

Low OPEX: Best in class fuel efficiency with O2E technology
Robust and Reliable Product: Lowest maintenance and trouble free product with Kirloskar Liquid Cooled Engines
Start Type: Controller Based Easy Push Start Type
Customer Service: Quick and affordable door step service coverage (420+ service touch points and 6000+ KOEL trained service professionals on field)
Warranty: 2 years warranty & labour free onsite service under warranty period
KRM: Critical genset parameters can be views on laptop or mobile
Enquire Now!
Prime Rating at rated rpm (as per ISO 8528)
kVA
180
200
250
kW
144
160
200
Genset Model
KG1-180WS
KG1-200ws
KG1-250WS
Frequency
Hz
50
50
50
Power Factor
lagging
0.8
0.8
0.8
Voltage
V
415 (3Ø)
415 (3Ø)
415 (3Ø)
Governing class (As per ISO 8528 Part – V)
G3
g3
G3
Noise Level
dBA
<75
<75
<75
Fuel Consumption*
At 100% Load
Ltrs/Hr
41.3
45.9
56.9
At 75% Load
30.9
34.4
42.6
At 50% Load
22.7
25.2
29.9
Fuel Tank Capacity
Ltrs
460
460
460
Weight of Genset with canopy°
Dry
Kg
3900
3900
4010
Wet
4300
4300
4320
Overall Dimensions of Genset^
Length
mm
4300
4340
4340
Width
1740
1740
1740
Height
1970
1970
1975
Electrical Battery Starting Voltage
Volts-DC
24
24
24
Engine
Engine Model
6SL1500TA G2
6SL1500TA G2
6SL1500TA G3
Rated output (Prime Continous rating as per ISO 8528-1
kW
183
183
228
HP
248
248
310
No. of Cylinder
Number
6
6
6
Cubic Capacity2 
Ltrs
8.86
8.86
8.86
Bose x Stroke
mm
118 x 135
118 X 135
118 X 135
Rated Speed
RPM
1500
1500
1500
Aspiration
NA/TC/TA
TA
TA
TA
Lube Oil Change Period
hrs
500
500
500
Lube Oil Sump Capacity
Ltrs
27
27
27
Cooling Mechanism
Liquid Cooled
Liquid Cooled
Liquid Cooled
Coolant Capacity
Ltrs
32
29.2
31.8
Alternator
Insulation Class
Class H
Class H
Class H
Ingression Protection
IP 23
IP 23
IP 23
Alternator Efficiency (at 100% load) 0.8pf**
%
93
93.5
93.6
Max Voltage Dip at Full Load 0.8 pf Lag
sec
<20%
<20%
<20%
Max Time to build up rated voltage at ated RPM
< 1 sec provided engine reach the rated speed
< 1 sec provided engine reach the rated speed
< 1 sec provided engine reach the rated speed
Short Circuit Ratio
0.53
0.545
0.45
Short Circuit Withstand Time
sec
3 time the rated current for < 3 sec
Overload Withstand Cpacity
%
10% overload for 1hr once in 12hrs
10% overload for 1hr once in 12hrs
10% overload for 1hr once in 12hrs
Notes:
  • ^ Tolerance Apply, *with 0.845 Specific Graity of Diesel (5% Tolerance)
  • ** Efficiency of Alternator as per standards IS 4722 and IEC 34-1
  • °These weight are for handling & transportation only
  • For Site Conditions other standard operating conditions consult available Prime Power

 
Disclaimer:

Due to continuous improvement in product on the basis of market feedback above specification are subject to change with out any prior notice. Please contact authorized dealer/distributor for latest specification.