750 kVA – 1010 kVA

 

Features

Lowest OPEX:
Best in class fuel efficiency with O2E technology
Lowest Footprint:
Smallest footprint in this range while meeting the performance & CPCB II Norms
Modular Control System :
Easily adapted to any configuration, viz standalone, interlocked, synchronised or grid connected
KOEL Green Alternator :
Built on globally renowned design. Patented winding design helps withstand operating harsh conditions.
KRM :
Critical genset parameters can be viewed on laptop or mobile
Customer Service:
Quick and affordable door step service coverage (420+ service touch points and 6000+ KOEL trained service professionals on field)
Warranty:
2 years warranty* & labour free onsite service under warranty period
Enquire Now!
Prime Rating at rated rpm (as per ISO 8528)
kVA
750 HD
1010 HD
kW
36
50
Genset Model
KG1-45WS
KG1-62.5WS
Frequency
Hz
50
50
Power Factor
lagging
0.8
0.8
Voltage
V
415 3Ø
415 3Ø
Governing class (As per ISO 8528 Part – V)
G2
G3
Noise Level
dBA
<75
Contact KOEL For Deatil
Fuel Consumption*
At 100% Load
Ltrs/Hr
154
199
At 75% Load
126.4
155
At 50% Load
89.7
112
Fuel Tank Capacity
Ltrs
990
990
Weight of Genset with canopy°
Dry
Kg
8300
13200
Wet
-
-
Overall Dimensions of Genset^
Length
mm
6800
7800
Width
2300
2300
Height
2713
2713
Electrical Battery Starting Voltage
Volts-DC
24
24
Engine
Engine Model
DV12ETA G1
DV16ETA
Rated output (Prime Continous rating as per ISO 8528-1
kW
662
889
HP
900
1210
No. of Cylinder
Number
12
16
Cubic Capacity2 
Ltrs
23.88
31.84
Bose x Stroke
mm
130 x 150
130 x 150
Rated Speed
RPM
1500
1500
Aspiration
NA/TC/TA
TA
TA
Lube Oil Change Period
hrs
500
500
Lube Oil Sump Capacity
Ltrs
53
130
Cooling Mechanism
Liquid Cooled
Liquid Cooled
Coolant Capacity
Ltrs
145
180
Alternator
Insulation Class
Class H
Class H
Ingression Protection
IP 23
IP 23
Alternator Efficiency (at 100% load) 0.8pf**
%
94.6
95.1
Max Voltage Dip at Full Load 0.8 pf Lag
sec
<16%
<20%
Max Time to build up rated voltage at ated RPM
< 1 sec provided engine reach the rated speed
< 1 sec provided engine reach the rated speed
Short Circuit Ratio
0.485
0.431
Short Circuit Withstand Time
sec
3 Times rated current for ‘10 sec’
3 Times rated current for ‘10 sec’
Overload Withstand Cpacity
%
10% overload for 1hr once in 12hrs
10% overload for 1hr once in 12hrs
Notes:
  • ^ Tolerance Apply, *with 0.845 Specific Graity of Diesel (5% Tolerance)
  • ** Efficiency of Alternator as per standards IS 4722 and IEC 34-1
  • °These weight are for handling & transportation only
  • For Site Conditions other standard operating conditions consult available Prime Power

 
Disclaimer:

Due to continuous improvement in product on the basis of market feedback above specification are subject to change with out any prior notice. Please contact authorized dealer/distributor for latest specification.