Features
Lowest OPEX: |
Best in class fuel efficiency with O2E technology |
Lowest Footprint: |
Smallest footprint in this range while meeting the performance & CPCB II Norms |
Modular Control System : |
Easily adapted to any configuration, viz standalone, interlocked, synchronised or grid connected |
KOEL Green Alternator : |
Built on globally renowned design. Patented winding design helps withstand operating harsh conditions. |
KRM : |
Critical genset parameters can be viewed on laptop or mobile |
Customer Service: |
Quick and affordable door step service coverage (420+ service touch points and 6000+ KOEL trained service professionals on field) |
Warranty: |
2 years warranty* & labour free onsite service under warranty period |
Prime Rating at rated rpm (as per ISO 8528) |
kVA |
750 HD |
1010 HD |
|
kW |
36 |
50 |
||
Genset Model |
KG1-45WS |
KG1-62.5WS |
||
Frequency |
Hz |
50 |
50 |
|
Power Factor |
lagging |
0.8 |
0.8 |
|
Voltage |
V |
415 3Ø |
415 3Ø |
|
Governing class (As per ISO 8528 Part – V) |
G2 |
G3 |
||
Noise Level |
dBA |
<75 |
Contact KOEL For Deatil |
|
Fuel Consumption* |
At 100% Load |
Ltrs/Hr |
154 |
199 |
At 75% Load |
126.4 |
155 |
||
At 50% Load |
89.7 |
112 |
||
Fuel Tank Capacity |
Ltrs |
990 |
990 |
|
Weight of Genset with canopy° |
Dry |
Kg |
8300 |
13200 |
Wet |
- |
- |
||
Overall Dimensions of Genset^ |
Length |
mm |
6800 |
7800 |
Width |
2300 |
2300 |
||
Height |
2713 |
2713 |
||
Electrical Battery Starting Voltage |
Volts-DC |
24 |
24 |
|
Engine |
||||
Engine Model |
DV12ETA G1 |
DV16ETA |
||
Rated output (Prime Continous rating as per ISO 8528-1 |
kW |
662 |
889 |
|
HP |
900 |
1210 |
||
No. of Cylinder |
Number |
12 |
16 |
|
Cubic Capacity2 |
Ltrs |
23.88 |
31.84 |
|
Bose x Stroke |
mm |
130 x 150 |
130 x 150 |
|
Rated Speed |
RPM |
1500 |
1500 |
|
Aspiration |
NA/TC/TA |
TA |
TA |
|
Lube Oil Change Period |
hrs |
500 |
500 |
|
Lube Oil Sump Capacity |
Ltrs |
53 |
130 |
|
Cooling Mechanism |
Liquid Cooled |
Liquid Cooled |
||
Coolant Capacity |
Ltrs |
145 |
180 |
|
Alternator |
||||
Insulation Class |
Class H |
Class H |
||
Ingression Protection |
IP 23 |
IP 23 |
||
Alternator Efficiency (at 100% load) 0.8pf** |
% |
94.6 |
95.1 |
|
Max Voltage Dip at Full Load 0.8 pf Lag |
sec |
<16% |
<20% |
|
Max Time to build up rated voltage at ated RPM |
< 1 sec provided engine reach the rated speed |
< 1 sec provided engine reach the rated speed |
||
Short Circuit Ratio |
0.485 |
0.431 |
||
Short Circuit Withstand Time |
sec |
3 Times rated current for ‘10 sec’ |
3 Times rated current for ‘10 sec’ |
|
Overload Withstand Cpacity |
% |
10% overload for 1hr once in 12hrs |
10% overload for 1hr once in 12hrs |
Notes:
- ^ Tolerance Apply, *with 0.845 Specific Graity of Diesel (5% Tolerance)
- ** Efficiency of Alternator as per standards IS 4722 and IEC 34-1
- °These weight are for handling & transportation only
- For Site Conditions other standard operating conditions consult available Prime Power
Disclaimer:
Due to continuous improvement in product on the basis of market feedback above specification are subject to change with out any prior notice. Please contact authorized dealer/distributor for latest specification.