40 kVA – 160* kVA

 

Koel iGreen Offerings

  • AMF as standard
  • KOEL remote Monitoring
  • Silencer inside canopy
  • Aesthetically enhanced genset
  • QR Code enabled genset
  • Multi-colour Status indicator

Features

Low OPEX:
Best in class fuel efficiency with O2E technology
Robust and Reliable Product:
Lowest maintenance and trouble free product with Kirloskar Engines
Option of Air Cooled and Water Cooled Engines
Compliance:
Latest Government Emission Norms CPCB II
Start Type:
Controller Based Easy Push Start Type
Customer Service:
Quick and affordable door step service coverage (420+ service touch points and 6000+ KOEL trained service professionals on field)
Warranty:
2 years warranty & labour free onsite service under warranty period
Enquire Now!
Prime Rating at rated rpm (as per ISO 8528)
kVA
5
7.5
10
12.5
15
20
25
30
40
45
62.5
82.5
100
125
160
kW
4
6
8
10
12
16
20
24
32
36
50
66
80
100
128
Genset Model
KG1-5AS3
KG1-7.5AS4
KG1-10AS5
KG1-12.5AS2
KG1-15AS
KG1-20WS
KG1-25WS
KG1-30WS
KG1-40WS
KG1-45WS
KG1-62.5WS
KG1-82.5WS
KG1-100WS
KG1-125WS
KG1-160WS
Frequency
Hz
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
Power Factor
lagging
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Voltage
V
230 (1Ø) & 415 (3Ø)
230 (1Ø) & 415 (3Ø)
230 (1Ø) & 415 (3Ø)
230 (1Ø) & 415 (3Ø)
230 (1Ø) & 415 (3Ø)
230 (1Ø) & 415 (3Ø)
230 (1Ø) & 415 (3Ø)
230 (1Ø) & 415 (3Ø)
415 3Ø
415 3Ø
415 3Ø
415 3Ø
415 3Ø
415 3Ø
415 3Ø
Governing class (As per ISO 8528 Part – V)
G2
G2
G2
G2
G2
G2
G2
G2
G2
G2
G2
G2
G3
G3
G3
Noise Level
dBA
<75
<75
<75
<75
<75
<75
<75
<75
<75
<75
<75
<75
<75
<75
<75
Fuel Consumption*
At 100% Load
Ltrs/Hr
1.6
2.21
3
3.45
4
5.1
5.8
7.6
9.2
10.3
14.1
18.8
21.9
27.4
36.6
At 75% Load
1.3
1.62
2.4
2.65
3
3.8
4.4
5.8
7.4
8.7
11.3
13.8
16.9
20.2
27.7
At 50% Load
1
1.21
1.8
1.94
2.2
2.7
2.9
4.4
5.5
5.9
7.5
9.9
12.2
15.3
19.1
Fuel Tank Capacity
Ltrs
50
50
50
50
65
65
65
65
100
100
150
150
230
230
300
Weight of Genset with canopy°
Dry
Kg
670
680
750
840
880
900
1135
1135
1215
1215
1420
1710
2040
2090
2730
Wet
720
730
800
890
930
950
1185
1185
1300
1300
1550
1840
2240
2290
3110
Overall Dimensions of Genset^
Length
mm
1417
1767
1767
1767
1740
2205
2500
2500
2750
2750
2900
3200
3200
3200
4000
Width
820
820
820
820
1050
950
950
950
1050
1050
1100
1100
1300
1300
1500
Height
1321
1328
1328
1321
1474
1294
1294
1294
1493
1493
1581
1595
1795
1795
1915
Electrical Battery Starting Voltage
Volts-DC
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
Engine
Engine Model
EA10 G1
EA10G1
EA16G1
EA16G1
HA294 G1
2R1040 G1
3R1040T G1
3R1040T G1
3R1040TA G1
3R1040TA G1
4R810TA G1
4R1040TA G1
4K1080TA G2
4K1080TA G2
6K1080TA G2
Rated output (Prime Continous rating as per ISO 8528-1
kW
7.3
7.3
11.8
11.8
15.1
18.8
24
30.9
41.2
41.2
61
74.8
114.7
114.7
147
HP
10
10
16
16
20.5
25.5
42
42
56
56
83
102
156
156
200
No. of Cylinder
Number
1
1
2
2
2
2
3
3
3
3
4
4
4
4
6
Cubic Capacity2 
Ltrs
0.95
0.95
1.56
1.56
1.88
2.08
3.12
3.12
3.12
3.12
3.24
4.16
4.32
4.32
6.48
Bose x Stroke
mm
102x116
102x116
95x110
95x110
100 x 120
105 x 120
105 x 120
105 x 120
105 x 120
105 x 120
96 x 112
105 x 120
105 x 125
105 x 125
105 x 125
Rated Speed
RPM
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
Aspiration
NA/TC/TA
NA
NA
NA
NA
NA
NA
TC
TC
TA
TA
TA
TA
TA
TA
TA
Lube Oil Change Period
hrs
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
Lube Oil Sump Capacity
Ltrs
3.5
3.5
6.5
6.5
5
5.5
8
8
8
8
10
10
14
14
18
Cooling Mechanism
Air Cooled
Air Cooled
Air Cooled
Air Cooled
Air Cooled
Liquid Cooled
Liquid Cooled
Liquid Cooled
Liquid Cooled
Liquid Cooled
Liquid Cooled
Liquid Cooled
Liquid Cooled
Liquid Cooled
Liquid Cooled
Coolant Capacity
Ltrs
NA
NA
NA
NA
NA
9
14.5
14.5
11.5
11.5
17.5
24
21
21
28
Alternator
Insulation Class
Class H
Class H
Class H
Class H
Class H
Class H
Class H
Class H
Class H
Class H
Class H
Class H
Class H
Class H
Class H
Alternator Efficiency (at 100% load) 0.8pf**
%
78.1
82.5
82.6
84.9
86
88.9
89
89
89.2
89.2
91
91.4
92
92.5
93
Max Voltage Dip at Full Load 0.8 pf Lag
sec
<20%
<20%
<20%
<20%
≤ 20%
≤ 16%
≤ 16%
≤ 16%
<16%
<16%
<20%
≤20%
≤20%
≤20%
≤20%
Max Time to build up rated voltage at ated RPM
<5 sec provided engine reach the rated speed
<5 sec provided engine reach the rated speed
<5 sec provided engine reach the rated speed
<5 sec provided engine reach the rated speed
<5 sec provided engine reach the rated speed
<5 sec provided engine reach the rated speed
<5 sec provided engine reach the rated speed
<5 sec provided engine reach the rated speed
<5 sec provided engine reach the rated speed
<5 sec provided engine reach the rated speed
<5 sec provided engine reach the rated speed
Voltage recovery time 6 sec
< 1 sec provided engine reach the rated speed
Notes:
  • ^ Tolerance Apply, *with 0.845 Specific Graity of Diesel (5% Tolerance)
  • ** Efficiency of Alternator as per standards IS 4722 and IEC 34-1
  • °These weight are for handling & transportation only
  • For Site Conditions other standard operating conditions consult available Prime Power

 
Disclaimer:

Due to continuous improvement in product on the basis of market feedback above specification are subject to change with out any prior notice. Please contact authorized dealer/distributor for latest specification.