Koel iGreen Offerings
- AMF as standard
- KOEL remote Monitoring
- Silencer inside canopy
- Aesthetically enhanced genset
- QR Code enabled genset
- Multi-colour Status indicator
Features
Low OPEX: |
Best in class fuel efficiency with O2E technology |
Robust and Reliable Product: |
Lowest maintenance and trouble free product with Kirloskar Engines |
Option of Air Cooled and Water Cooled Engines |
|
Compliance: |
Latest Government Emission Norms CPCB II |
Start Type: |
Controller Based Easy Push Start Type |
Customer Service: |
Quick and affordable door step service coverage (420+ service touch points and 6000+ KOEL trained service professionals on field) |
Warranty: |
2 years warranty & labour free onsite service under warranty period |
Prime Rating at rated rpm (as per ISO 8528) |
kVA |
5 |
7.5 |
10 |
12.5 |
15 |
20 |
25 |
30 |
40 |
45 |
62.5 |
82.5 |
100 |
125 |
160 |
|
kW |
4 |
6 |
8 |
10 |
12 |
16 |
20 |
24 |
32 |
36 |
50 |
66 |
80 |
100 |
128 |
||
Genset Model |
KG1-5AS3 |
KG1-7.5AS4 |
KG1-10AS5 |
KG1-12.5AS2 |
KG1-15AS |
KG1-20WS |
KG1-25WS |
KG1-30WS |
KG1-40WS |
KG1-45WS |
KG1-62.5WS |
KG1-82.5WS |
KG1-100WS |
KG1-125WS |
KG1-160WS |
||
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
|
Power Factor |
lagging |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
|
Voltage |
V |
230 (1Ø) & 415 (3Ø) |
230 (1Ø) & 415 (3Ø) |
230 (1Ø) & 415 (3Ø) |
230 (1Ø) & 415 (3Ø) |
230 (1Ø) & 415 (3Ø) |
230 (1Ø) & 415 (3Ø) |
230 (1Ø) & 415 (3Ø) |
230 (1Ø) & 415 (3Ø) |
415 3Ø |
415 3Ø |
415 3Ø |
415 3Ø |
415 3Ø |
415 3Ø |
415 3Ø |
|
Governing class (As per ISO 8528 Part – V) |
G2 |
G2 |
G2 |
G2 |
G2 |
G2 |
G2 |
G2 |
G2 |
G2 |
G2 |
G2 |
G3 |
G3 |
G3 |
||
Noise Level |
dBA |
<75 |
<75 |
<75 |
<75 |
<75 |
<75 |
<75 |
<75 |
<75 |
<75 |
<75 |
<75 |
<75 |
<75 |
<75 |
|
Fuel Consumption* |
At 100% Load |
Ltrs/Hr |
1.6 |
2.21 |
3 |
3.45 |
4 |
5.1 |
5.8 |
7.6 |
9.2 |
10.3 |
14.1 |
18.8 |
21.9 |
27.4 |
36.6 |
At 75% Load |
1.3 |
1.62 |
2.4 |
2.65 |
3 |
3.8 |
4.4 |
5.8 |
7.4 |
8.7 |
11.3 |
13.8 |
16.9 |
20.2 |
27.7 |
||
At 50% Load |
1 |
1.21 |
1.8 |
1.94 |
2.2 |
2.7 |
2.9 |
4.4 |
5.5 |
5.9 |
7.5 |
9.9 |
12.2 |
15.3 |
19.1 |
||
Fuel Tank Capacity |
Ltrs |
50 |
50 |
50 |
50 |
65 |
65 |
65 |
65 |
100 |
100 |
150 |
150 |
230 |
230 |
300 |
|
Weight of Genset with canopy° |
Dry |
Kg |
670 |
680 |
750 |
840 |
880 |
900 |
1135 |
1135 |
1215 |
1215 |
1420 |
1710 |
2040 |
2090 |
2730 |
Wet |
720 |
730 |
800 |
890 |
930 |
950 |
1185 |
1185 |
1300 |
1300 |
1550 |
1840 |
2240 |
2290 |
3110 |
||
Overall Dimensions of Genset^ |
Length |
mm |
1417 |
1767 |
1767 |
1767 |
1740 |
2205 |
2500 |
2500 |
2750 |
2750 |
2900 |
3200 |
3200 |
3200 |
4000 |
Width |
820 |
820 |
820 |
820 |
1050 |
950 |
950 |
950 |
1050 |
1050 |
1100 |
1100 |
1300 |
1300 |
1500 |
||
Height |
1321 |
1328 |
1328 |
1321 |
1474 |
1294 |
1294 |
1294 |
1493 |
1493 |
1581 |
1595 |
1795 |
1795 |
1915 |
||
Electrical Battery Starting Voltage |
Volts-DC |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
|
Engine |
|||||||||||||||||
Engine Model |
EA10 G1 |
EA10G1 |
EA16G1 |
EA16G1 |
HA294 G1 |
2R1040 G1 |
3R1040T G1 |
3R1040T G1 |
3R1040TA G1 |
3R1040TA G1 |
4R810TA G1 |
4R1040TA G1 |
4K1080TA G2 |
4K1080TA G2 |
6K1080TA G2 |
||
Rated output (Prime Continous rating as per ISO 8528-1 |
kW |
7.3 |
7.3 |
11.8 |
11.8 |
15.1 |
18.8 |
24 |
30.9 |
41.2 |
41.2 |
61 |
74.8 |
114.7 |
114.7 |
147 |
|
HP |
10 |
10 |
16 |
16 |
20.5 |
25.5 |
42 |
42 |
56 |
56 |
83 |
102 |
156 |
156 |
200 |
||
No. of Cylinder |
Number |
1 |
1 |
2 |
2 |
2 |
2 |
3 |
3 |
3 |
3 |
4 |
4 |
4 |
4 |
6 |
|
Cubic Capacity2 |
Ltrs |
0.95 |
0.95 |
1.56 |
1.56 |
1.88 |
2.08 |
3.12 |
3.12 |
3.12 |
3.12 |
3.24 |
4.16 |
4.32 |
4.32 |
6.48 |
|
Bose x Stroke |
mm |
102x116 |
102x116 |
95x110 |
95x110 |
100 x 120 |
105 x 120 |
105 x 120 |
105 x 120 |
105 x 120 |
105 x 120 |
96 x 112 |
105 x 120 |
105 x 125 |
105 x 125 |
105 x 125 |
|
Rated Speed |
RPM |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
|
Aspiration |
NA/TC/TA |
NA |
NA |
NA |
NA |
NA |
NA |
TC |
TC |
TA |
TA |
TA |
TA |
TA |
TA |
TA |
|
Lube Oil Change Period |
hrs |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
|
Lube Oil Sump Capacity |
Ltrs |
3.5 |
3.5 |
6.5 |
6.5 |
5 |
5.5 |
8 |
8 |
8 |
8 |
10 |
10 |
14 |
14 |
18 |
|
Cooling Mechanism |
Air Cooled |
Air Cooled |
Air Cooled |
Air Cooled |
Air Cooled |
Liquid Cooled |
Liquid Cooled |
Liquid Cooled |
Liquid Cooled |
Liquid Cooled |
Liquid Cooled |
Liquid Cooled |
Liquid Cooled |
Liquid Cooled |
Liquid Cooled |
||
Coolant Capacity |
Ltrs |
NA |
NA |
NA |
NA |
NA |
9 |
14.5 |
14.5 |
11.5 |
11.5 |
17.5 |
24 |
21 |
21 |
28 |
|
Alternator |
|||||||||||||||||
Insulation Class |
Class H |
Class H |
Class H |
Class H |
Class H |
Class H |
Class H |
Class H |
Class H |
Class H |
Class H |
Class H |
Class H |
Class H |
Class H |
||
Alternator Efficiency (at 100% load) 0.8pf** |
% |
78.1 |
82.5 |
82.6 |
84.9 |
86 |
88.9 |
89 |
89 |
89.2 |
89.2 |
91 |
91.4 |
92 |
92.5 |
93 |
|
Max Voltage Dip at Full Load 0.8 pf Lag |
sec |
<20% |
<20% |
<20% |
<20% |
≤ 20% |
≤ 16% |
≤ 16% |
≤ 16% |
<16% |
<16% |
<20% |
≤20% |
≤20% |
≤20% |
≤20% |
|
Max Time to build up rated voltage at ated RPM |
<5 sec provided engine reach the rated speed |
<5 sec provided engine reach the rated speed |
<5 sec provided engine reach the rated speed |
<5 sec provided engine reach the rated speed |
<5 sec provided engine reach the rated speed |
<5 sec provided engine reach the rated speed |
<5 sec provided engine reach the rated speed |
<5 sec provided engine reach the rated speed |
<5 sec provided engine reach the rated speed |
<5 sec provided engine reach the rated speed |
<5 sec provided engine reach the rated speed |
Voltage recovery time 6 sec |
< 1 sec provided engine reach the rated speed |
Notes:
- ^ Tolerance Apply, *with 0.845 Specific Graity of Diesel (5% Tolerance)
- ** Efficiency of Alternator as per standards IS 4722 and IEC 34-1
- °These weight are for handling & transportation only
- For Site Conditions other standard operating conditions consult available Prime Power
Disclaimer: