320 kVA – 625 kVA

 

Features

Lowest OPEX: Best in class fuel efficiency with O2E technology
Lowest Footprint: Smallest footprint in this range while meeting the performance & CPCB II Norms
Modular Control System : Easily adapted to any configuration, viz standalone, interlocked, synchronised or grid connected
KOEL Green Alternator : Built on globally renowned design. Patented winding design helps withstand operating harsh conditions.
KRM : Critical genset parameters can be viewed on laptop or mobile
Customer Service: Quick and affordable door step service coverage (420+ service touch points and 6000+ KOEL trained service professionals on field)
Warranty: 2 years warranty* & labour free onsite service under warranty period
Enquire Now!
Prime Rating at rated rpm (as per ISO 8528)
kVA
180
200
250
320 HD
380 HD
400 HD
500 HD
600 HD
625 HD
kW
144
160
200
256
304
320
400
480
500
Genset Model
KG1-180WS
KG1-200ws
KG1-250WS
KG1-320WS
KG1-380WS
KG1-400WS
KG1-500WS
KG1-600WS
KG1-625WS
Frequency
Hz
50
50
50
50
50
50
50
50
50
Power Factor
lagging
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Voltage
V
415 (3Ø)
415 (3Ø)
415 (3Ø)
415 (3Ø)
415 (3Ø)
415 (3Ø)
415 (3Ø)
415 (3Ø)
415 3Ø
Governing class (As per ISO 8528 Part – V)
G3
g3
G3
G3
G3
G3
G2
G3
G3
Noise Level
dBA
<75
<75
<75
<75
<75
<75
<75
<75
<75
Fuel Consumption*
At 100% Load
Ltrs/Hr
41.3
45.9
56.9
69
83.3
86.9
107.5
125.9
130.5
At 75% Load
30.9
34.4
42.6
52.5
61.2
65.1
81.9
94.2
98.6
At 50% Load
22.7
25.2
29.9
37.6
44.1
46
57.1
63.8
66.2
Fuel Tank Capacity
Ltrs
460
460
460
850
850
850
990
990
990
Weight of Genset with canopy°
Dry
Kg
3900
3900
4010
5910
6000
6050
7200
770
7800
Wet
4300
4300
4320
-
-
-
-
-
-
Overall Dimensions of Genset^
Length
mm
4300
4340
4340
5100
5375
5375
5650
6660
6660
Width
1740
1740
1740
2000
2000
2000
2000
2000
2000
Height
1970
1970
1975
2408
2408
2408
2558
2710
2710
Electrical Battery Starting Voltage
Volts-DC
24
24
24
24
24
24
24
24
24
Engine
Engine Model
6SL1500TA G2
6SL1500TA G2
6SL1500TA G3
DV8TA G1
DV8TA G2
DV8TA G3
DV10TA G1
DV12TA G1
DV12TA G2
Rated output (Prime Continous rating as per ISO 8528-1
kW
183
183
228
294
346
360
447
532
552
HP
248
248
310
400
470
490
608
723
750
No. of Cylinder
Number
6
6
6
8
8
8
10
12
12
Cubic Capacity2 
Ltrs
8.86
8.86
8.86
15.92
15.92
15.92
19.9
23.88
23.88
Bose x Stroke
mm
118 x 135
118 X 135
118 X 135
130 x 150
130 x 150
130 x 150
130 x 150
130 x 150
130 x 150
Rated Speed
RPM
1500
1500
1500
1500
1500
1500
1500
1500
1500
Aspiration
NA/TC/TA
TA
TA
TA
TA
TA
TA
TA
TA
TA
Lube Oil Change Period
hrs
500
500
500
500
500
500
500
500
500
Lube Oil Sump Capacity
Ltrs
27
27
27
44
44
44
50
53
53
Cooling Mechanism
Liquid Cooled
Liquid Cooled
Liquid Cooled
Liquid Cooled
Liquid Cooled
Liquid Cooled
Liquid Cooled
Liquid Cooled
Liquid Cooled
Coolant Capacity
Ltrs
32
29.2
31.8
55
115
115
120
145
145
Alternator
Insulation Class
Class H
Class H
Class H
Class H
Class H
Class H
Class H
Class H
Class H
Ingression Protection
IP 23
IP 23
IP 23
IP 23
IP 23
IP 23
IP 23
IP 23
IP 23
Alternator Efficiency (at 100% load) 0.8pf**
%
93
93.5
93.6
93.8
93.3
93.4
94.6
94.8
95.9
Max Voltage Dip at Full Load 0.8 pf Lag
sec
<20%
<20%
<20%
<20%
≤ 20%
≤ 20%
≤ 20%
≤ 20%
≤ 20%
Max Time to build up rated voltage at ated RPM
< 1 sec provided engine reach the rated speed
< 1 sec provided engine reach the rated speed
< 1 sec provided engine reach the rated speed
< 1 sec provided engine reach the rated speed
< 1 sec provided engine reach the rated speed
< 1 sec provided engine reach the rated speed
< 1 sec provided engine reach the rated speed
< 1 sec provided engine reach the rated speed
< 1 sec provided engine reach the rated speed
Short Circuit Ratio
0.53
0.545
0.45
0.55
0.418
0.422
0.477
0.432
0.414
Short Circuit Withstand Time
sec
3 time the rated current for < 3 sec
< 3
3 Times rated current for ‘10 sec’
3 Times rated current for ‘10 sec’
3 Times rated current for ‘10 sec’
3 Times rated current for ‘10 sec’
3 Times rated current for ‘10 sec’
Overload Withstand Cpacity
%
10% overload for 1hr once in 12hrs
10% overload for 1hr once in 12hrs
10% overload for 1hr once in 12hrs
10% overload for 1hr once in 12hrs
10% overload for 1hr once in 12hrs
10% overload for 1hr once in 12hrs
10% overload for 1hr once in 12hrs
10% overload for 1hr once in 12hrs
10% overload for 1hr once in 12hrs
Notes:
  • ^ Tolerance Apply, *with 0.845 Specific Graity of Diesel (5% Tolerance)
  • ** Efficiency of Alternator as per standards IS 4722 and IEC 34-1
  • °These weight are for handling & transportation only
  • For Site Conditions other standard operating conditions consult available Prime Power

 
Disclaimer:

Due to continuous improvement in product on the basis of market feedback above specification are subject to change with out any prior notice. Please contact authorized dealer/distributor for latest specification.